Why is transposition necessary in CTC?

If you’ve ever worked with large-scale power transformers or high-voltage apparatus, you’ve probably heard the phrase “transposed conductors” tossed around in technical meetings. As a supplier of continuously transposed conductors (CTCs), I get asked a lot by engineers and design teams: Why go through the hassle of transposing strands instead of just using a solid copper bar or simple parallel wires? It’s a fair question—transposing adds a step in manufacturing, and it’s not the cheapest part of the process. But the answer ties directly to some of the most critical challenges in high-voltage equipment: eddy current losses, thermal performance, and long-term reliability. Let’s break this down, because skipping transposition isn’t just a small oversight—it can lead to equipment failure, wasted energy, and costly downtime. Continuously Transposed Conductors

First, let’s ground this in how transformer windings work. A large power transformer’s windings carry very high AC currents—sometimes tens of thousands of amps—to step voltage up or down for transmission or distribution. When current flows through a conductor in an AC environment, it creates a time-varying magnetic field. That magnetic field doesn’t just affect the transformer’s core; it also interacts with the other conductors in the same winding, and even with parallel strands within a single winding turn. If you use untransposed parallel strands, each strand sits at a different distance from the core, which means each experiences a different magnetic flux. The strands closer to the core are exposed to a stronger magnetic field, so they have higher induced voltage, while the ones farther out have lower induced voltage. When you connect these strands in parallel (which you have to do to handle high current, since a single thick conductor would be too inflexible and hard to wind), this voltage difference causes circulating current to flow between the strands. That’s the root of the problem most people miss.

Circulating currents are a silent killer. Unlike the useful load current that powers the transformer, these currents only circulate within the group of parallel strands. They don’t contribute to the transformer’s function—they just generate heat and waste energy as extra I²R losses. I’ve seen cases where a transformer’s winding was built with untransposed strands, and the circulating current losses added 3-5% extra to the transformer’s total no-load loss. For a transformer that runs 24/7, that’s millions of dollars in wasted electricity over its 30+ year lifespan. Worse, the localized heat from concentrated circulating current can degrade the conductor’s insulation over time. Insulation breakdown in a transformer winding is catastrophic—it can lead to a short circuit, a fire, and days or weeks of downtime, not to mention the cost of replacing the unit.

Now, let’s talk about how transposition fixes that. A continuously transposed conductor is made of multiple thin copper (or aluminum) strands, insulated from each other with a thin layer of enamel or paper. Instead of laying these strands straight along the length of the winding, we transpose them at regular intervals. That means each strand moves to the position of the next strand in the group at specific points along the conductor’s length. For a winding with, say, 4 parallel strands, each strand will spend an equal amount of time in the inner position (closer to the core, higher flux) and the outer position (farther from the core, lower flux). Over the entire length of the winding, the average induced voltage across each strand is identical, so there’s no voltage difference to drive circulating current. That eliminates those extra I²R losses entirely—at least, it does if the transposition is done correctly, at the right intervals, and consistently along the winding.

But it’s not just about eliminating circulating current. There’s another type of loss at play here: skin effect. When AC current flows through a conductor, the current tends to concentrate in the outer portion of the conductor cross-section. That’s the skin effect, and it gets more severe as the frequency goes up or the conductor gets thicker. For high-current transformers, a solid conductor thick enough to carry 10,000 amps would have most of its current flowing in just the top few millimeters—meaning a huge chunk of the copper is basically unused. If you split that thick conductor into multiple parallel strands and transpose them, you make the cross-section of each strand small enough that skin effect is negligible for the operating frequency. Combined with transposition to fix circulating currents, this lets you use nearly 100% of the conductor’s cross-sectional area for carrying load current, instead of wasting it on unused copper or extra losses.

Wait, I know some engineers will say, “Can’t we just use strands with the same cross-section and skip transposition?” The answer is no, because even if the strands are identical, their position relative to the magnetic field isn’t. Let’s do a quick mental experiment: imagine a winding laid around a round transformer core. The innermost strand is at radius R1 from the core center, the next at R2, and so on, up to the outermost at Rn. The magnetic flux through a circle of radius r is proportional to r, right? So each strand sees a different flux, even if they’re the same size. Without transposition, the innermost strand always has the highest flux, the outermost always the lowest, so voltage differences build up. If you transpose once per turn, each strand flips positions once every turn, so over 1,000 turns of a large transformer, every strand has an average position exactly in the middle. That equalizes the flux, eliminates the voltage difference, and kills the circulating current.

I’ve been in this industry for 18 years, and I’ve seen two common mistakes that engineers make when they skimp on transposition. The first is using a low number of transpositions, or transposing too far apart. If transpositions are spaced every 10 meters instead of every meter, the strands don’t switch positions enough to equalize the flux. That leaves small voltage differences, which lead to small circulating currents that add up over time. The second mistake is using non-continuous transposition, like splicing strands and transposing at splices instead of along the conductor length. Splicing is a weak point for insulation, and uneven splices can create hot spots even if transposition is technically present. That’s why CTC is so critical: it’s a single, continuous conductor transposed along its entire length, with no splices in the transposed section. That consistency is what makes it effective for high-voltage, high-current applications.

Another angle is thermal management. Transformers are limited by their hot-spot temperature—if the winding gets too hot, the insulation degrades faster, cutting the transformer’s lifespan. Transposition doesn’t just reduce loss; it also makes the heat distribution more uniform. With circulating currents localized to certain parts of untransposed strands, those parts get much hotter than others. Transposing spreads the load current evenly across all strands, and eliminates circulating current hot spots, so the hot-spot temperature is lower. That means the transformer can run closer to its design capacity without overheating, and it will last longer. I’ve had a client who swapped their old untransposed winding for CTC last year, and their hot-spot temperature dropped by 7 degrees Celsius. That translates to a 15% longer insulation life, per the standard aging curves used in transformer design. It’s a small change with a big payoff.

Let’s also talk about applications where transposition is non-negotiable. We supply CTC for large power transformers, but also for generators, high-current reactors, and even some superconducting devices. For superconducting magnets, which carry extremely high current, circulating currents from untransposed strands would create not just heat (which quenches the superconductor) but also uneven current distribution that could damage the magnet. In grid-scale transformers, which are designed to operate for 30-40 years, every loss adds up over decades. A 1% loss reduction in a 100 MVA transformer is 1 MW of power wasted every hour—over a year, that’s 8,760 MWh, which is enough to power 1,000 average homes for a year. Multiply that by tens of thousands of transformers across a grid, and transposition isn’t just a technical detail—it’s a key part of energy efficiency and sustainability.

I know some smaller transformer makers might think, “For our 1 MVA transformers, transposition is overkill.” But even for smaller units, if you’re using parallel strands for high current, transposition can still make a difference. The math scales down too—circulating losses are proportional to the square of the current difference, so even a small current difference in 1,000 amps can add up. The key is matching the transposition interval to the conductor size and operating frequency. For 50/60 Hz power systems, the transposition interval is usually between 50 cm and 2 meters, depending on the number of strands. For higher-frequency applications like railway traction transformers, you need shorter intervals, because skin effect and circulating currents get worse with frequency. That’s another advantage of CTC: we can customize transposition intervals, strand count, and insulation type to match the specific application, whether it’s a grid transformer or a traction unit.

Now, let’s address the counterarguments I’ve heard from skeptical designers. Some say, “Transposition adds cost to the conductor.” Sure, it does—our CTC is priced slightly higher than untransposed parallel strands. But when you factor in the energy savings, the reduced risk of failure, and the longer lifespan of the transformer, the ROI is almost always positive. I’ve seen a client who calculated that the extra cost of CTC for a 200 MVA transformer was recouped in less than 2 years from lost energy costs, not to mention avoiding a potential $500,000 transformer replacement and downtime. For critical infrastructure like grid transformers, reliability isn’t a luxury—it’s a requirement. Skimping on transposition to save a few thousand dollars on conductor costs is a false economy.

Another counter: “We can compensate for circulating losses with cooling systems.” Again, that’s a band-aid. Adding extra cooling increases the size and cost of the transformer, takes up space in the substation, and still wastes energy on the circulating losses. It’s far more efficient to eliminate the source of the loss entirely with transposition. Cooling systems work in parallel with good conductor design, but they can’t fix the root problem of uneven current distribution.

At the end of the day, transposition is necessary because it solves a fundamental problem in parallel AC conductors: the combination of uneven magnetic flux and parallel current paths that lead to wasted energy, heat, and reliability issues. Continuously transposed conductors make that transposition consistent, uniform, and easy to integrate into winding designs, which is why they’re the standard in high-voltage, high-current equipment today.

If you’re a transformer designer, a maintenance engineer, or a project manager working on a large electrical apparatus, I get that you have a lot of variables to balance: cost, performance, reliability, lead time. Transposition is one of those variables that’s easy to overlook, but it has a disproportionate impact on how your equipment performs over its lifespan. For our part, we’ve specialized in CTC for over a decade, so we can help you design the right conductor for your specific application, whether you’re building a new transformer or upgrading an existing winding.

If you’re ready to discuss your next project, need help calculating the right transposition specification, or just have questions about how CTC can improve your equipment, reach out to our team to connect for a procurement conversation. We’re here to share our expertise and find a solution that works for your needs.

Enameled Round Wire References

  1. McNutt, W. J. (1974). Eddy current losses in transformer windings. IEEE Transactions on Power Apparatus and Systems, PAS-93(4), 1168-1176.
  2. Del Vecchio, R. M., et al. (2002). Transformer Design Principles: With Applications to Core-Form Power Transformers. CRC Press.
  3. IEEE Std C57.12.90-2015, Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers.
  4. Sullivan, C. R. (2010). Equivalent circuit analysis of eddy current and circulating current losses in litz wire and transposed conductors. IEEE Transactions on Power Electronics, 25(6), 1509-1517.
  5. Karsai, K., et al. (1987). Large Power Transformers. Elsevier.