If you’ve ever stared at a vial of DNA, RNA, or protein samples and wondered how scientists turn those tiny, invisible molecules into the crisp, colorful bands you see in research papers, gel electrophoresis is the answer. It’s one of the most foundational, workhorse techniques in molecular biology, used in everything from identifying genetic mutations to verifying PCR products and testing for pathogens. But if you’re new to lab work or need a quick, reliable refresher to set up your unit correctly, this step-by-step guide walks you through exactly how to do it—plus a few pro tips I’ve picked up over 15 years as a laboratory instrument supplier, helping labs of all sizes from university teaching labs to biotech startups avoid common, costly mistakes. Laboratory Instruments

First, let’s start with the basics you’ll need to grab before you even open your electrophoresis unit. You can’t build anything without the right parts, right? Here’s your core list, all stuff I recommend keeping stocked in your lab so you don’t hit a mid-procedure rush: your horizontal or vertical gel electrophoresis unit (I sell both, and which you pick depends entirely on your sample type: horizontal is standard for nucleic acids like DNA/RNA, vertical is for proteins like antibodies), agarose (for nucleic acid gels—opt for molecular-grade, it’s cheaper per use than regular agarose and avoids background smearing), tris buffer (we use 1X TAE or 1X TBE, depending on your application: TAE is better for long DNA fragments, TBE for smaller, more precise separations), DNA loading dye (this is the stuff that makes your samples sink into the gel wells, not float away, and also lets you track how far your samples are moving as the run happens), a DNA stain (ethidium bromide is classic, but SYBR Safe is less toxic and works just as well for most labs), a power supply (make sure it’s rated for at least 300 volts, and has consistent current—fluctuating power is the #1 cause of uneven bands), a micropipette with sterile tips, and a ruler. Oh, and don’t forget gloves and safety goggles—you’re handling lab-grade chemicals, so no exceptions.
Now, the first actual step in setting up your gel is pouring the agarose gel itself, which is the “filter” that separates your molecules. Most labs skip this part if they use pre-cast gels, but making your own is cheaper for high-throughput work and gives you more control over gel concentration. Here’s how to do it right: first, pick your gel concentration. If you’re working with small DNA fragments (under 500 base pairs), use a 2% agarose gel; for medium fragments (500-20,000 bp), a 1% gel works; for large fragments, use 0.5% gel. Too high, and you’ll crush small molecules so they can’t move; too low, and big molecules will run right off the end of the gel. I see new labs mess this up all the time, so double-check that number before you weigh your agarose.
Next, measure your correct amount of agarose powder into an Erlenmeyer flask, then add your 1X TAE or TBE buffer. The rule here is 1 gram of agarose per 100 mL of buffer, right? Yep, that’s where the percentage comes from. Now, you need to melt the agarose to turn it from a powder into a clear liquid. The fastest way is to microwave it in 30-second bursts, swirling between each, until it’s completely melted—no little white flakes left. Be careful though, it gets boiling hot, so use a mitt. Once it’s melted, let it cool for 2 to 3 minutes—if you pour it too hot, it’ll warp the gel casting tray and the comb you use to make sample wells.
Now, this is where pro tip #1 comes in: add your DNA stain right now, before you pour the gel. I’ve had so many customers who pour the gel, then try to add stain to the running buffer later, and they end up with uneven staining or bands that are too dim. Add it at the manufacturer’s recommended concentration—usually 1 μL of SYBR Safe per 100 mL of gel, so that’s perfect. Swirl gently to mix, then pour the liquid agarose into your gel casting tray. Most casting trays have little rubber gaskets to seal the ends, so double-check those are in place otherwise your gel will leak out.
Now, insert the comb. This is the plastic or silicone piece with tiny teeth that creates the wells where you load your samples later. Place it at the end of the casting tray, about 1 to 2 mm above the bottom surface of the tray—if it’s too low, your wells will be too close to the edge of the gel, and samples will run off the sides; too high, and your loading tip will hit the bottom of the well and break it. Once the comb is in place, let the gel set for 20 to 30 minutes at room temperature—don’t rush this, if you move it too soon, the gel will be soft and fall apart when you remove the comb.
While you’re waiting, you can prep your samples, but let’s get the gel set up in the electrophoresis chamber first. Once your gel is solid, you need to remove the comb, and now you have little sample wells. Next, take the gel (still on the casting tray, or you can lift it off if it’s a pre-cast tray) and place it into the electrophoresis unit. Make sure the wells are at the negative electrode end—yes, this is critical. DNA is negatively charged, so it will move from negative to positive when you turn on the power. If you flip the gel, your samples will run backward, and you’ll get a mess of bands, not separated ones. I’ve even heard of a teaching lab that flipped a gel and ran their PCR samples toward the negative electrode, and they wasted an entire week’s work—so that’s a rule: wells = negative, far end = positive.
Now, add running buffer to the unit. You want it to cover the gel by about 1 to 2 millimeters—if it’s too shallow, the electric current won’t spread evenly, so bands will be uneven and smudged; too deep, and your samples will float out of the wells when you load them. Top it up if needed until the gel is fully submerged.
Next, load your samples. This part is where gentle technique matters. Take your micropipette, set it to 5 to 10 μL (adjust based on your well size), and attach a sterile tip. First, mix your sample with loading dye—loading dye has glycerol, which is heavier than the buffer, so it makes your sample sink into the well instead of floating away. The standard ratio is 4 parts sample to 1 part loading dye, so 8 μL sample + 2 μL loading dye is perfect.
Now, lower the pipette tip just above the well, and slowly dispense the sample. If you push too fast, you’ll blow the sample out of the well, or even puncture the bottom of the well. If you’re loading a molecular weight ladder (the standard set of DNA fragments of known sizes, to measure your samples against), load that in the first well so you can compare bands later. Leave a couple of empty wells between your samples if you have a lot—this prevents bands from smearing into each other. Once all your samples are loaded, that’s the setup done, right? Wait, almost—connect the power supply.
Here’s another pro tip: never turn on the power until you double-check the connections. The black cable is negative, so it connects to the electrode near your sample wells; the red cable is positive, connects to the far end. If you mix them up again, samples run backward, and you might blow out a fuse in your power supply. Now, set the voltage. For most standard gels, 100 volts is ideal—this gives a slow, consistent run that separates bands clearly. If you use too high a voltage, you’ll get heat buildup, which warps the gel and makes bands smudge; too low, and the run will take forever, and small fragments might diffuse. Run the gel until the loading dye has moved about 2/3 of the way down the gel—usually 45 minutes to an hour, depending on voltage and gel size.
Once the run is done, turn off the power first, then disconnect the cables, take the gel out, and you can visualize it with a UV transilluminator or a gel doc system. That’s the basic setup, but wait—there are a few common mistakes even experienced labs make, so let’s cover those to save you time and money. First, buffer degradation: if you re-use your TAE or TBE buffer too many times, it gets old, the pH changes, and that messes with the electric charge, leading to uneven bands. I recommend changing buffer every 3 runs, or at least every week if you run gels daily. Second, gel bubbles: when you pour the agarose, if you get bubbles on the bottom of the gel, that creates a little hole in the gel that will mess up sample movement. If you see bubbles when you’re pouring, just tap the flask gently or use a pipette tip to pop them before the gel sets. Third, overloading samples: adding too much DNA (more than 500 nanograms per well) will create a big, smudged band that’s hard to distinguish, so start with 10-20 ng per sample and adjust from there.
Now, if you’re using pre-cast gels instead of making your own (which is great if you’re low on time or need consistent gels for high-throughput work), the setup is even simpler. Most pre-cast horizontal gels come in a sealed tray; you just remove the seal, place the tray into the unit, add running buffer, load your samples, and run. No pouring, no waiting for gels to set—perfect for busy labs. I keep a stock of pre-cast gels in my inventory for exactly this reason; they’re a lifesaver for teaching labs that run gels for 20 students a week.
Whether you’re a graduate student setting up your first gel for a thesis project, a lab manager restocking your instrument inventory, or a teacher demonstrating molecular biology for a class, getting the setup right is the difference between clear, usable results and a frustrating, smudged mess. The key things to remember: match your gel concentration to your fragment size, place wells at the negative electrode, add enough buffer to cover the gel, and double-check your power connections.

I’ve worked with labs across the globe for years, and I’ve seen first-hand how a correctly set up electrophoresis unit speeds up research, reduces waste, and gives you reliable results every time. If you’re looking to upgrade your electrophoresis equipment, restock on supplies, or just have questions about which unit works best for your lab’s needs, I’m here to help. Reach out to my team to discuss your requirements, get personalized recommendations, and make sure your lab has everything you need to run smooth, successful gels.
Concrete Testing Instrument References:
- Sambrook J, Russell DW. Molecular Cloning: A Laboratory Manual. 4th ed. Cold Spring Harbor Laboratory Press; 2012.
- Thermo Fisher Scientific. Agarose Gel Electrophoresis for Nucleic Acids. Technical Guide. 2021.
- Bio-Rad Laboratories. Horizontal Electrophoresis Systems: Setup and Operation Guide. 2019.
- Current Protocols in Molecular Biology. Agarose Gel Electrophoresis. John Wiley & Sons; 2001.